UPS output power rating (0,9 p.f.) |
kVA |
8 |
10 |
12 |
15 |
20 |
30 |
40 |
kW |
7,2 |
9 |
10,8 |
13,5 |
18 |
27 |
36 |
General |
Efficiency in double conversion mode (full load) |
92% |
93% |
Efficiency in double conversion mode (half load) |
90% |
91% |
Distributed paralleling with Hot Sync technology |
4 |
Field upgradeable |
yes |
Inverter/rectifier topology |
transformer-free IGBT with PWM |
Audible noise |
< 50 dB |
Colour |
RAL 7035 |
Input |
Nominal voltage rating (configurable) |
220/380, 230/400, 240/415 V 50/60 Hz |
With external transformer |
e.g. 230, 400, 440, 480, 690 V |
With internal transformer |
e.g. 230, 400, 440, 480, 690 V |
Input voltage range |
Low -20% at 100% load/-50% at 50% load without battery discharge; High +10%/max +20% |
Input frequency range |
45-65 Hz |
Input power factor |
0,99 |
Input ITHD |
less than 4,5% |
Soft start capability |
Yes |
Internal backfeed protection |
Yes |
Output |
Nominal voltage rating (configurable) |
220/380, 230/400, 240/415 V 50/60 Hz |
With internal transformer |
e.g. 230, 440, 480, 690 V |
Output UTHD |
<3% (100% linear load); <5% (reference non linear load) |
Output power factor |
0,9 (e.g. 9 kW at 10 kVA) |
0,9 (e.g. 27 kW at 30 kVA) |
Permitted load power factor |
0,7 lagging - 0,8 leading |
Battery |
Type |
Maintenance-free VRLA batteries, NiCd |
Charging method |
ABM technology or Float |
Temperature compensation |
Optional |
Battery nominal voltage (lead-acid) |
384 V (32x12 V, 192 cells) |
432 V (36x12 V, 216 cells) |
Charging current / Model |
Default 3 A
*Max 30 A |
Default 3 A
*Max 60 A |
*May be limited by maximum UPS input current rating |
Accessories |
|
Isolation transformer, long-life batteries, external battery cabinets, UPS Center (input, bypass, distribution), X-Slot connectivity (Web/SNMP, ModBus/ Jbus, Relay, Hot Sync, ViewUPS-X remote display), Hot Sync parallel tie cabinet, integrated manual bypass, external maintenance bypass switch |
Isolation transformer, long-life batteries, external battery cabinets, X-Slot connectivity (Web/SNMP, ModBus/ Jbus, Relay, Hot Sync, ViewUPS-X remote display), Hot Sync parallel tie cabinet, integrated manual bypass, external maintenance bypass switch |
Communications |
X-Slot |
2 communication bays |
Serial ports |
1 available |
Relay inputs/outputs |
2/1 programmable |
Compliance with standards |
Safety (CB certified) |
IEC 62040-1, IEC 60950-1 |
EMC |
IEC 62040-2, IEC 60945 |
Performance |
IEC 62040-3 |
Approvals |
CE, DNV Type Approval, BV Type Approval and ABS PDA up to 15kVA |
Other classification survey reports |
On request |